{"product_id":"25uf-capacitor","title":"25UF CAPACITOR⚙️","description":"\u003cp data-start=\"0\" data-end=\"25\"\u003e🟦 \u003cstrong data-start=\"3\" data-end=\"25\"\u003ePRODUCT FACT SHEET\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"27\" data-end=\"141\"\u003e\u003cstrong data-start=\"27\" data-end=\"44\"\u003eProduct Name:\u003c\/strong\u003e 25μF Motor Start\/Run Capacitor\u003cbr data-start=\"75\" data-end=\"78\"\u003e\u003cstrong data-start=\"78\" data-end=\"94\"\u003eApplication:\u003c\/strong\u003e Pool Pumps, Spa Pumps, General Electric Motors\u003c\/p\u003e\n\u003chr data-start=\"143\" data-end=\"146\"\u003e\n\u003cp data-start=\"148\" data-end=\"497\"\u003e✅ \u003cstrong data-start=\"150\" data-end=\"174\"\u003eProduct Description:\u003c\/strong\u003e\u003cbr data-start=\"174\" data-end=\"177\"\u003eThe \u003cstrong data-start=\"181\" data-end=\"200\"\u003e25 μF Capacitor\u003c\/strong\u003e is a reliable start\/run capacitor designed for single-phase electric motors commonly found in pool pumps, spa pumps, and other household or industrial motors. It provides stable electrical support during motor operation, helping improve start-up torque and ensuring smooth, efficient performance.\u003c\/p\u003e\n\u003chr data-start=\"499\" data-end=\"502\"\u003e\n\u003cp data-start=\"504\" data-end=\"893\"\u003e⚙️ \u003cstrong data-start=\"507\" data-end=\"524\"\u003eKey Features:\u003c\/strong\u003e\u003cbr data-start=\"524\" data-end=\"527\"\u003e🔹 \u003cstrong data-start=\"530\" data-end=\"554\"\u003e25 Microfarad Rating\u003c\/strong\u003e – Precisely matched for pumps requiring a 25μF capacitor\u003cbr data-start=\"611\" data-end=\"614\"\u003e🔹 \u003cstrong data-start=\"617\" data-end=\"636\"\u003eHigh Durability\u003c\/strong\u003e – Heat, moisture, and vibration resistant\u003cbr data-start=\"678\" data-end=\"681\"\u003e🔹 \u003cstrong data-start=\"684\" data-end=\"710\"\u003eBoosts Start-Up Torque\u003c\/strong\u003e – Helps motors start smoothly under load\u003cbr data-start=\"751\" data-end=\"754\"\u003e🔹 \u003cstrong data-start=\"757\" data-end=\"782\"\u003eLong Operational Life\u003c\/strong\u003e – Ideal for continuous-duty motors\u003cbr data-start=\"817\" data-end=\"820\"\u003e🔹 \u003cstrong data-start=\"823\" data-end=\"848\"\u003eUniversal Replacement\u003c\/strong\u003e – Suitable for most 240V pool \u0026amp; spa motors\u003c\/p\u003e\n\u003chr data-start=\"895\" data-end=\"898\"\u003e\n\u003cp data-start=\"900\" data-end=\"922\"\u003e📐 \u003cstrong data-start=\"903\" data-end=\"922\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"924\" data-end=\"1422\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"924\" data-end=\"983\"\u003e\n\u003ctr data-start=\"924\" data-end=\"983\"\u003e\n\u003cth data-start=\"924\" data-end=\"948\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"948\" data-end=\"983\" data-col-size=\"sm\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1045\" data-end=\"1422\"\u003e\n\u003ctr data-start=\"1045\" data-end=\"1105\"\u003e\n\u003ctd data-start=\"1045\" data-end=\"1069\" data-col-size=\"sm\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd data-start=\"1069\" data-end=\"1105\" data-col-size=\"sm\"\u003e25 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1106\" data-end=\"1166\"\u003e\n\u003ctd data-start=\"1106\" data-end=\"1130\" data-col-size=\"sm\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd data-start=\"1130\" data-end=\"1166\" data-col-size=\"sm\"\u003e450V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1167\" data-end=\"1227\"\u003e\n\u003ctd data-start=\"1167\" data-end=\"1191\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"1191\" data-end=\"1227\" data-col-size=\"sm\"\u003eMotor Start \/ Run Capacitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1228\" data-end=\"1288\"\u003e\n\u003ctd data-start=\"1228\" data-end=\"1252\" data-col-size=\"sm\"\u003eShape\u003c\/td\u003e\n\u003ctd data-start=\"1252\" data-end=\"1288\" data-col-size=\"sm\"\u003eCylindrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1289\" data-end=\"1356\"\u003e\n\u003ctd data-start=\"1289\" data-end=\"1313\" data-col-size=\"sm\"\u003eTerminals\u003c\/td\u003e\n\u003ctd data-start=\"1313\" data-end=\"1356\" data-col-size=\"sm\"\u003e2-prong or lead-wire depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1357\" data-end=\"1422\"\u003e\n\u003ctd data-start=\"1357\" data-end=\"1381\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"1381\" data-end=\"1422\" data-col-size=\"sm\"\u003ePool pumps, spa pumps, general motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1424\" data-end=\"1427\"\u003e\n\u003cp data-start=\"1429\" data-end=\"1458\"\u003e🛠️ \u003cstrong data-start=\"1433\" data-end=\"1456\"\u003eInstallation Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1459\" data-end=\"1813\"\u003e\n\u003cli data-start=\"1459\" data-end=\"1523\"\u003e\n\u003cp data-start=\"1461\" data-end=\"1523\"\u003eEnsure power is disconnected before replacing the capacitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1524\" data-end=\"1577\"\u003e\n\u003cp data-start=\"1526\" data-end=\"1577\"\u003eReplace \u003cstrong data-start=\"1534\" data-end=\"1566\"\u003eonly with the same μF rating\u003c\/strong\u003e (25 μF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1578\" data-end=\"1657\"\u003e\n\u003cp data-start=\"1580\" data-end=\"1657\"\u003eVoltage rating can be equal or higher, but \u003cem data-start=\"1623\" data-end=\"1636\"\u003enever lower\u003c\/em\u003e than the original.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1658\" data-end=\"1740\"\u003e\n\u003cp data-start=\"1660\" data-end=\"1740\"\u003eA failing capacitor may cause humming, tripping breakers, or failure to start.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1813\"\u003e\n\u003cp data-start=\"1743\" data-end=\"1813\"\u003eVisually check for swelling or leaking—replace immediately if found.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Poolstore Australia","offers":[{"title":"Default Title","offer_id":41982237343798,"sku":"Z9276","price":69.9,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0593\/5562\/7574\/files\/25uf_capacitor_1.jpg?v=1707883342","url":"https:\/\/poolstoreaustralia.myshopify.com\/products\/25uf-capacitor","provider":"Poolstore Australia ","version":"1.0","type":"link"}